Please use this identifier to cite or link to this item: http://dspace.dtu.ac.in:8080/jspui/handle/repository/23514
Title: REMOTE HEART RATE ESTIMATION FROM FACIAL VIDEOS, HEURISTIC RECTANGULAR ROIS AND PSD-DRIVEN SIGNAL ANALYSIS(RPPG)
Authors: VERMA, RAVI
Kumar, Manjeet (SUPERVISOR)
Keywords: REMOTE PHOTOPLETHYSMOGRAPHY
HEART RATE ESTIMATION
HEURISTIC RECTANGULAR ROI
DELAUNAY TRIANGULATION
CR CHROMINANCE CHANNEL
INDEPENDENT COMPONENT ANALYSIS
MEDIAPIPE FACE MESH
BANDPASS FILTER ING
POWER SPECTRAL DENSITY
WELCH METHOD
UBFC-RPPG
RPPG
Issue Date: Jun-2026
Series/Report no.: TD-9311;
Abstract: Heart rate is basic indicators of cardiovascular health, measuring it Continuousl in daily life requires direct contact of optcal sensors with the body. Remote photoplethysmography (rPPG) challenges such dependence by recovering the cardiac pulse signal from the faint, rhythmic color fluctuations that changes in blood volume cause on exposed skin. These changes are not apparent to human vision, but digital RGB cameras can consistently monitor them. Heuristic rectangular region-of-interest (ROI) selection on the face and power spectral density (PSD) driven frequency analysis of the extracted rPPG signal are the main contributions of my thesis, which is a fully non-contact, training-free heart rate estimation method. Themethod begins with dense facial landmark detection using MediaPipe Face Mesh,which provides 468 landmark points on the face as per photo frame . Delaunay triangulation is then applied to these landmarks, and make 898 mesh of non-overlapping triangles on the face form the connection of these landmark points.The suggested technique produces three facial proportional rectangular ROIs one over the center forehead and one over each cheek—derived from the overall face bounding box using defined normalized offsets, as opposed to using all triangulated patches arbitrarily.Utilizing the well-known finding that the forehead and both cheek regions show intense, consistent blood perfusion and are relatively unaffected by lip and jaw motion, only triangles whose geometric centroids fall within these heuristic rectangles are kept for signal extraction. This heuristic rectangle selection method is computationally simple and free from training data, adjusts to any facial size or picture resolution, and eliminates the requirement for labeling. Every triangular area of an image is changes from RGB to YCrCb color space, and the mean value of the Cr chrominance channel is calculated using a pre computed binary mask. The Cr component encodes the red-minus-luma differential, providing some protection to global light drift. Stacking per-triangle temporal means produces a signal matrix of dimensionsframes × triangles. This matrix’s columns are bandpass filtered using a second-order Butterworth filter spanning 0.8–3.0Hz (approximately 48–180bpm) To reduce both low-frequency postural drift and high-frequency noise. FastICA is used on the filtered matrix to distinguish statistically independent source signals, Welch PSD analysis identifies the component with the highest concentration of spectral energy inside the cardiac band as the rPPG signal of relevance. Finally, the major frequency peak occurs inside the range 0.8–3.0Hz i physiological window that is identified from the Welch PSD estimate of this component and it converted to BPM by the given formula via: 𝐻𝑅 = 60 × 𝑓peak (bpm). The system has been evaluated using the UBFC-rPPG Dataset 2. Across the 32 topics it achieved a MA of 82.4% and a MAE of 18.24bpm, Subjects having covered ROIs on the forehead or cheeks by glasses reflections, thick facial hair, or partial occlusion experienced poor performance. Whenjust22unoccludedindividualsareincluded, theMAEdropto6.52bpmand accuracy rises to 93.0%, The solution performs similarly to traditional methods like CHROM and POS on comparable benchmarks. It operates on a normal CPU no need of GPU or any offline training. The study found that structured heuristic ROI selection, Cr-channel extraction, and PSD-driven analysis provide a lightweight baseline for contactless heart rate monitoring. However, future work should focus on adaptive, skin-aware ROI refinement.
URI: http://dspace.dtu.ac.in:8080/jspui/handle/repository/23514
Appears in Collections:M.E./M.Tech. Electronics & Communication Engineering

Files in This Item:
File Description SizeFormat 
Ravi Verma M.Terch.pdf9.02 MBAdobe PDFView/Open
Ravi Verma plag.pdf6.5 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.