| dc.description.abstract | Delhi, situated in Seismic Zone IV as per IS 1893:2016, faces significant seismic hazard, yet a large proportion of its building stock remains unassessed for earthquake vulnerability. This thesis presents a systematic seismic vulnerability assessment of buildings in selected localities of Delhi using the Rapid Visual Screening (RVS) methodology prescribed in FEMA P-154 (2015). The study covers two primary building typologies: Reinforced concrete (RC) framed government and residential buildings, and unreinforced brick masonry (URM) structures in informal settlements, representing the broad spectrum of Delhi’s built environment. Field investigations were carried out across three study areas — Azadpur, Akshardham, and Samaypur Badli — encompassing nine formally screened buildings subjected to both Level 1 and Level 2 RVS, supplemented by photographic RVS of informal settlement clusters near Samaypur Badli, Haiderpur Badli. Score modifiers accounting for vertical irregularity, plan irregularity, soil conditions, and code compliance were applied in accordance with the FEMA P-154 framework. The results reveal a pronounced generational divide in seismic performance. Post benchmark RC buildings designed and constructed after 2014 to modern code provisions achieved high Level 2 RVS scores (SL2 = 2.6 to 3.4), corresponding to very low probabilities of collapse under Maximum Considered Earthquake (MCE) shaking. In contrast, pre-code RC government buildings constructed between 1975 and 1979 exhibited substantially higher vulnerability, with Level 2 scores as low as SL2 = 0.1, translating to a failure probability of 1 in 1.25 under MCE shaking. The photographic RVS of informal settlements identified a consistent pattern of systemic vulnerabilities including extreme rooftop overloading from unanchored water storage tanks, absence of horizontal reinforcing bands at plinth, sill, lintel, and roof levels, zero or sub-code inter-building separation distances, soft storey conditions at commercial ground floors, informal vertical additions without structural assessment, and narrow emergency access lanes of 1.0 to 3.0 metres width. These conditions collectively indicate a high probability of widespread structural failure and mass casualty risk in the event of a moderate to severe seismic event in these settlements.The study validates the representative building approach as a resource-efficient and technically defensible method for area-wide seismic risk assessment. Given the structural homogeneity of Delhi’s government building cohorts and informal settlement typologies, findings from screened representative buildings can be extended with reasonable confidence to structurally analogous buildings across entire settlement zones. Buildings 2, 7, 8, and 9 are recommended for immediate detailed structural evaluation, with Buildings 7 and 9 receiving highest priority. The thesis concludes that a significant and largely unquantified seismic risk exists in Delhi’s pre-code and informal building stock, and that the RVS methodology provides a scientifically credible, scalable framework to initiate systematic seismic risk characterisation, prioritisation, and mitigation across Indian cities with comparable urban vulnerability profiles. | en_US |
| dc.language.iso | en | en_US |
| dc.relation.ispartofseries | TD-9310; | - |
| dc.subject | RAPID VISUAL SCREENING | en_US |
| dc.subject | MCE SHAKING | en_US |
| dc.title | RAPID VISUAL SCREENING OF BUILDINGS | en_US |
| dc.type | Thesis | en_US |
| Appears in Collections: | M.E./M.Tech. Civil Engineering | |