Please use this identifier to cite or link to this item:
http://dspace.dtu.ac.in:8080/jspui/handle/repository/23510| Title: | ASSESSING STRUCTURAL INTEGRITY OF STEEL FIBRE REINFORCED CONCRETE ELEMENTS UNDER ELEVATED TEMPERATURE USING EMI TECHNIQUE |
| Authors: | AGHA, WESAM AL Pal, Shilpa ( SUPERVISIOR ) Dev, Nirendra (CO-SUPERVISOR) |
| Keywords: | ASSESSING STRUCTURAL INTEGRITY EMI TECHNIQUE STEEL FIBRE REINFORCED CONCRETE ELEVATED TEMPERATURE |
| Issue Date: | Oct-2026 |
| Series/Report no.: | TD-9304; |
| Abstract: | Steel Fibre Reinforced Concrete (SFRC) improves the post-cracking behaviour of concrete because the steel fibres bridge developing cracks. However, the interaction among the cementitious matrix, fibres and cracks makes its condition difficult to assess. Destructive tests determine material properties at specified ages or after loading, whereas non-destructive tests record the response at the chosen test times and points. This thesis evaluates the Electromechanical Impedance (EMI) technique as a laboratory Structural Health Monitoring (SHM) method for monitoring SFRC during curing, mechanical loading and heating. The analysis combines piezoelectric measurements, resonance characteristics, statistical indices, Equivalent Structural Parameters (EPS) and data driven prediction. The research addresses three objectives. The first assesses piezoelectric sens ing for monitoring material development and mechanically induced change in fibre reinforced concrete. The second examines how heating time and temperature affect the measured EMI response and evaluates a compensation procedure for separating temperature effects from structural changes. The third investigates data-driven models that relate EMI measurements to the mechanical responses obtained in the experiments. Four connected experimental studies were conducted using two sensor configurations. Jacketed Piezo Sensors (JPS) were embedded and retained in four monitored SFRC cubes. A Non-Bonded Piezo Sensor (NBPS) was coupled at a fixed test point and removed before destructive testing, allowing the same sensing arrangement to be used with separate specimens. The curing study considered four SFRC configurations containing hooked-end steel fibres with aspect ratios of 55 and 65 and dosages of 0.50% and 0.75%. One JPS was embedded in each monitored cube, and EMI measurements were recorded at ten curing ages from 1 to 180 days. Separate cubes were tested in compression to provide age-dependent mechanical reference data. Changes in resonance frequency, peak conductance, statistical indices and the extracted equivalent mass, stiffness and damping were examined together. The changes depended on the fibre configuration and were largest during the early curing period. For two monitored configurations, equivalent stiffness had a linear relationship with the corresponding compressive strength, with reported R2 values of 0.94 and 0.96. Within the tested specimens, these results show that the local coupled sensor–concrete response changed as curing progressed. Mechanical-damage assessment used separate groups of 39 cubes and 39 cylin ders. Each group contained thirteen material configurations with three specimens per configuration. The reusable NBPS was positioned before the compression and splitting tensile tests and returned to the same point after loading to obtain paired EMI signatures. The highest measured mean compressive strengths in the cube group were 60.95 MPa for aspect ratio 65 and 59.90 MPa for aspect ratio 55, both at 0.75% fibre dosage. In the cylinder group, the highest measured mean splitting-tensile strengths were 6.68 MPa and 6.34 MPa for aspect ratios 65 and 55, respectively, at the upper tested dosage of 1.50%. The paired signatures, statistical indices and EPS responses varied with material configuration and loading mode. Selected high-dosage cylinder records also showed an increase in local resonance frequency after splitting-tensile loading. Because the viii response was measured at one sensor position, these results identify local condition changes but do not locate damage throughout the structural element. The same four JPS-instrumented cubes used for curing monitoring were subse quently tested under controlled heating. EMI signatures were recorded from 75 to 250◦C at 25◦C intervals and after three holding periods, first in the intact condition and then after introducing a 3-mm-wide and 30-mm-deep saw cut. The two configurations containing 0.75% fibre have saw-cut records only up to 175◦C, whereas the 0.50% configurations extend to 250◦C. Temperature changed the frequency and amplitude of the conductance and susceptance features. An uncompensated signature therefore can not be treated as a damage response without comparison at the same temperature. The evaluated Enhanced Effective Frequency Shift (E–EFS) procedure combines interpo lated frequency alignment, a joint conductance–susceptance shift search and correction of the mean offset in each channel. It reduced the RMSD value for every available comparison within the same structural condition, although the remaining difference generally increased at the higher temperatures. The procedure improves comparison of the tested records but does not establish a universal compensation limit or damage threshold. Three data-driven studies were conducted separately for the hydration, compres sion and splitting-tensile experiments. The methods included conventional Machine Learning regressors and Deep Learning models based on Convolutional Neural Net works, Long Short-Term Memory networks, Bidirectional Long Short-Term Memory networks and their hybrid combinations. Model ranking depended on the measured response and material configuration. The cube-compression study favoured squared exponential Gaussian Process Regression, whereas the splitting-tensile studies identified different neural-network models for the two aspect-ratio groups. The hydration models also related EMI inputs to compressive strength with high reported coefficients of determination. These results show that study-specific regression can be performed for the available experimental data. The conclusions remain limited to the training and test divisions used in each study; validation based on independent specimen groups and external data is required before application to other structures. The principal contribution of the thesis is the combined use of retained embedded sensing and reusable non-bonded sensing in curing, mechanical-loading and thermal studies of SFRC. Resonance features, statistical measures and model-derived EPS provide different measures of change in the local coupled response. The work also establishes an experimental basis for comparison at different temperatures and for estimating mechanical responses from EMI measurements. Potential applications in clude laboratory material development, construction-stage monitoring and comparative condition assessment where repeatable sensor coupling and suitable baselines can be maintained. The conclusions apply to the investigated materials, specimen geometries, fibre configurations, sensor arrangements, excitation ranges, loading procedures and tem perature conditions. The monitored JPS configurations represent individual physical specimens, and the NBPS findings were obtained from controlled groups of laboratory specimens rather than full-scale structures. Future work should therefore examine replicated embedded specimens, long-term coupling stability, larger structural elements, combined mechanical and environmental actions, independent data and validation based on separate specimen groups. Such studies are required to establish repeatability, transferability and reliable criteria for field application. |
| URI: | http://dspace.dtu.ac.in:8080/jspui/handle/repository/23510 |
| Appears in Collections: | Ph.D. Civil Engineering |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| WESAM AL AGHA Ph.D.pdf | 22.88 MB | Adobe PDF | View/Open | |
| WESAM AL AGHA plag.pdf | 24.13 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.