Please use this identifier to cite or link to this item: http://dspace.dtu.ac.in:8080/jspui/handle/repository/23502
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDARWADE, NITISHA SUDHIR-
dc.contributor.authorNagarajan, S. T. (SUPERVISOR)-
dc.date.accessioned2026-11-25T07:56:38Z-
dc.date.available2026-11-25T07:56:38Z-
dc.date.issued2025-12-
dc.identifier.urihttp://dspace.dtu.ac.in:8080/jspui/handle/repository/23502-
dc.description.abstractOngoing global transition to sustainable and low-carbon energy systems has accelerated the integration of inverter-based resources (IBRs) including photovoltaic (PV) systems, wind turbines (WT), and battery energy storage systems (BESS) into modern power grids. This transition introduces new technical challenges for system operation, stability and protection. Traditionally, power systems relied on synchronous generators (SGs) as the primary sources of electricity generation. SGs inherently provide several advantageous characteristics including significant rotational inertia, robust fault current characteristics and predictable electromechanical dynamics. These properties ensured stable system operation and reliable coordination of protection schemes. In contrast, IBRs are grid-interfaced through power electronic converters, which do not contribute physical inertia and exhibit fundamentally different dynamic behavior during both normal and faulted conditions. IBRs fast control-based responses alter system frequency dynamics of conventional stability assessment tools and compromise the effectiveness of impedance and directional based protection schemes. As the share of IBRs increases, power systems exhibit accelerated frequency excursions, higher rates of change of frequency (ROCOF), reduced frequency nadirs, altered inter-area oscillatory behavior and heightened vulnerability to transient and small-signal instability. These changes disrupt the assumptions supporting conventional protection schemes such as distance relays, directional relays, differential relays and power swing blocking (PSB) functions. Protection elements designed for predictable voltage and current responses may maloperate when exposed to converter-driven fault currents, distorted waveforms, or rapidly evolving system impedances. Specifically, negative-sequence relays lose dependability under IBR driven fault characteristics, while distance relays exhibit reach inaccuracies due to distorted apparent impedance. The PSB function also becomes less effective, as it finds difficulty to distinguish true power swings from IBR-induced oscillations. Together, these factors necessitate a comprehensive re-evaluation of power system stability and protection under high renewable penetration, supported by advanced measurement and control methods. The work carried out addresses these challenges through three primary contributions. First, it systematically assesses the impact of IBR integration on power system stability across transient, small-signal, and frequency domains. The research quantifies how reduced inertia and altered fault contributions affect stability margins, oscillatory behavior and wide-area interactions, with particular emphasis on inter-area oscillations, converter-driven modes, and spatial distribution of renewable generation. v vi Second, it investigates the performance of key protection schemes under high IBR penetration. The study evaluates negative-sequence-impedance-based directional relaying (67Q) under unsymmetrical fault conditions, analyzing negative sequence voltage (V₂), current (I₂), and their phase relationships to determine fault direction. In parallel, it examines the vulnerability of impedance-based distance relays and PSB functions to distorted or limited fault currents and accelerated power swings. By modelling both fault and swing scenarios, the research highlights under-reaching, over-reaching, delayed operation, and misclassification risks that arise when traditional relay logic interacts with low-inertia systems. Third, the thesis develops and validates a novel methodology for real-time system inertia estimation. Recognizing that inertia is not directly measurable, the approach leverages phasor measurement units (PMUs) to capture synchronized, high resolution bus voltage phase angles. Exploiting the close relationship between generator rotor angle oscillations and bus voltage phase angle oscillations, the derivative of phase angle is extracted and processed through a fuzzy logic inference system to estimate system inertia (Hsystem). This technique achieves high estimation accuracy (96.13%–99.98%) without relying on assumptions about frequency behavior, enabling effective inertia tracking under varying IBR penetration levels and providing actionable insights for adaptive protection, frequency control and emergency response. Simulation studies employ benchmark power system models including the IEEE nine-bus system, the single-machine infinite bus system, and Kundur’s two-area system, all modified to incorporate PV-based renewable generation. High-fidelity electromagnetic transient (EMT) simulations are performed in real time using OPAL RT’s HYPERSIM environment with a simulation step size of 50 microseconds, capturing fast transient phenomena occurring within microseconds to milliseconds. Time-domain simulations using PMU data further evaluate system response and protection behavior under various fault conditions. Collectively, the results highlight that IBRs significantly alter the fault characteristics observed by conventional protection schemes, especially under negative sequence components. Directional overcurrent relays based on negative sequence impedance exhibit reduced sensitivity and accuracy, potentially leading to delayed or incorrect fault identification. Similarly, distance relays experience degraded performance under high IBR penetration, as reduced fault current levels and altered apparent impedance measurements can cause under-reach or over-reach conditions. Consequently, these relays may operate incorrectly or fail to detect faults within their intended protection zones. In addition, distance relay equipped with conventional PSB functions fail to differentiate between stable power swings and faults in low-inertia systems, increasing the risk of relay maloperation and system instability. The proposed inertia estimation technique, by contrast, provides a reliable and adaptive foundation for future protection and control schemes, offering system operators real-time visibility of inertia variations. vi vii This thesis establishes a comprehensive framework for evaluating stability, protection challenges, and inertia estimation in contemporary power systems. By implementing real-time simulations and adopting PMU-based techniques on standard benchmark models, this thesis provides enhanced insights into wide-area monitoring and supports secure operation in renewable integrated power systems. The insights gained underscore the urgent need to redesign and adapt existing protection algorithms and stability assessment tools to accommodate the growing presence of IBRs and to develop resilient, flexible, and sustainable electric grids capable of withstanding disturbances as the energy transition accelerates. Key Contributions of the Thesis • Comprehensive Stability Assessment: Systematic evaluation of transient, small-signal, and frequency stability in benchmark test systems under varying levels of IBR penetration. • Protection Scheme Analysis: In-depth investigation of negative-sequence impedance-based directional relaying (67Q) performance under various faults with IBR integration. • Distance Relay and PSB Evaluation: Detailed study of impedance-based distance protection and power swing blocking (PSB) functions under reduced inertia and distorted fault currents, identifying maloperation risks. • Novel Real-Time Inertia Estimation Method: Development of a PMU-based technique using bus voltage phase angle derivatives and fuzzy logic to estimate system inertia online. • Real-Time Validation: Implementation and testing of the proposed methods in the OPAL-RT HYPERSIM environment, providing high-fidelity validation under realistic conditions.en_US
dc.language.isoenen_US
dc.relation.ispartofseriesTD-9296;-
dc.subjectRENEWABLE ENERGY SOURCESen_US
dc.subjectPOWERS SYSTEM STABILITYen_US
dc.subjectPSB FUNCTIONen_US
dc.subjectCOMPREHENSIVE STABILITY ASSESSMENTen_US
dc.subjectREAL-TIME VALIDATIONen_US
dc.subjectPROTECTION SCHEME ANALYSISen_US
dc.titleIMPACT OF RENEWABLE ENERGY SOURCES ON POWERS SYSTEM STABILITYen_US
dc.typeThesisen_US
Appears in Collections:Ph.D. Electrical Engineering

Files in This Item:
File Description SizeFormat 
Nitisha Sudhir Darwade Ph.D..pdf5.98 MBAdobe PDFView/Open
Nitisha Sudhir Darwade plag.pdf5.88 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.