dc.description.abstractIn present scenario buildings with floating column is a typical feature in the modern multistory construction in urban India. Such features are highly undesirable in building built in seismically active areas. This study highlights the importance of explicitly recognizing the presence of the floating column in the analysis of building. Alternate measures, involving stiffness balance of the first storey and the storey above, are proposed to reduce the irregularity introduced by the floating columns. The study is carried out on a building with floating columns. The plan layout of the building is shown in the figure. The building considered is a residential building having G+9. Height of each storey is kept same as other prevalent data.en_US